Search results for "Gamma camera"

showing 8 items of 8 documents

A new principle to normalize plasma concentrations allowing single-sample clearance determinations in both children and adults.

1992

A sufficiently accurate quantification of renal function requiring only one plasma sample without an additional gamma-camera study has, until now, only been possible in adults. A new principle will be presented here allowing the universal application of known algorithms, regardless of the clearance substance used, by normalizing the plasma concentrations with respect to the individual body dimensions of the patients - for infants as well as for adults. In this respect, algorithms are developed for clearance determinations using technetium-99m mercaptoacetyltriglycine (99mTc-MAG3), which are based on steady-state studies as the reference. They allow the calculation of quantitative clearance …

AdultAdolescentRenal functionSingle sampleKidneylaw.inventionRenal CirculationTechnetium Tc 99m MertiatidelawBlood plasmaMedicineHumansRadiology Nuclear Medicine and imagingChildRadionuclide ImagingGamma camerabusiness.industryInfant NewbornInfantGeneral MedicineOrganotechnetium CompoundsStandard errorChild PreschoolPlasma concentrationbusinessNuclear medicineQuantitative analysis (chemistry)OligopeptidesAlgorithmsBlood samplingEuropean journal of nuclear medicine
researchProduct

Emission tomography with a large-hole collimator (CACAO): a possible new way to improve radionuclide imaging.

2002

This work aims to improve the quality of scintigraphy. It evaluates the use of a large-hole collimator, the Computer Aided Collimation Gamma Camera Project (CACAO), in SPECT. Acquisition data from the same object were simulated for CACAO and for a conventional collimator. Better signal-to-noise ratios were found for CACAO images, whatever the number of emitted photons. This work demonstrates that high-resolution images may be obtained with large-hole collimators. The combination of CACAO and pixilated detectors may further improve radionuclide imaging.

Image qualityImage processingIterative reconstructionCollimated light030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineOpticslawImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imaging[SDV.NEU] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]Radionuclide ImagingComputingMilieux_MISCELLANEOUSGamma camera[SDV.IB] Life Sciences [q-bio]/BioengineeringPhotonsbusiness.industryDetectorCollimator030220 oncology & carcinogenesisCalibration[SDV.IB]Life Sciences [q-bio]/Bioengineering[SDV.NEU]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]TomographybusinessNuclear medicineAlgorithmsJournal of computer assisted tomography
researchProduct

CMOS Photodiode Design for Gamma Camera Application

2008

We designed new photodiodes sensors including current mirror amplifiers. These photodiodes have been fabricated using a CMOS 0.6 micrometers process from Austria Micro System (AMS). The photodiode areas are respectively 1 mm × 1 mm and 0.4 mm × 0.4 mm with fill factor 98% and total chip area is 2 square millimetres. The sensor pixels show a logarithmic response in illumination and are capable of detecting very low blue light (less than 0.5 lux) . These results allow to use our sensor in new gamma camera solid-state concept.

Materials sciencePixelbusiness.industryAmplifierPhotodetectorChiplaw.inventionPhotodiodeCurrent mirrorCMOSlawOptoelectronicsbusinessGamma camera2008 IEEE International Conference on Signal Image Technology and Internet Based Systems
researchProduct

First tests of the applicability of gamma-ray imaging for background discrimination in time-of-flight neutron capture measurements

2015

In this work we explore for the first time the applicability of using $\gamma$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a $^{197}$Au sample have been carried out at n_TOF, achieving an enhancement of a factor…

Nuclear and High Energy PhysicsPhotomultiplierPhysics - Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaNuclear physics01 natural scienceslaw.invention99-00Total energy detectorsOpticsData acquisitionRaigs gammalaw0103 physical sciencesγ-ray imagingmsc:00-01Detectors and Experimental TechniquesFacility n-tof010306 general physicsInstrumentationNuclear ExperimentNeutron capture cross-sectionsGamma cameraPhysicsNeutrons010308 nuclear & particles physicsbusiness.industryAstrophysics::Instrumentation and Methods for AstrophysicsTime-of-flight methodData-acquisition systemNeutron radiationSample (graphics)Pulse-height weighting techniqueNeutron captureTime of flightgamma-ray imagingCernPinhole (optics):Física::Física molecular [Àrees temàtiques de la UPC]Física nuclearbusinessSimulation
researchProduct

The intraoperative use of the mini-gamma camera (MGC) in the surgical treatment of primary hyperparathyroidism Technical reports and immediate result…

2015

The intraoperative use of the mini-gamma camera(MGC) in the surgical treatment of primary hyperpathyroidism.Technical reports and immediate results from the initial experience INTRODUCTION: The treatment of primary hyperparathyroidism consists almost exclusively in the parathyroidectomy. The preoperative imaging (ultrasonography, 99mTc sestamibi scan) can allow to localize the pathologic gland and perform minimally-invasive focused techniques, but in presence of ectopic or intrathyroidal glands, parathyroid hyperplasia or coexistent thyroid disease,the sensitivity of these imaging techniques worsens. The present study shows a new technique of preoperative scintigraphic imaging and describes…

ParathyroidectomyPrimary hyperparathyroidismIntraoperative minigamma cameraParathyroid scintigraphy
researchProduct

Quantitative Determination of Renal 99mTc-MAG3 Clearance. A Comparison of Results Acquired Simultaneously in Whole Body Geometry and with a Gamma Cam…

1997

289 patients were simultaneously investigated with a partially shielded whole body counter (Oberhausen) and in camera technique to correlate the values of the MAG3-clearance. Good correlation was found for the often used times schedules of taking blood samples. Late blood samples increase high clearance values in both methods slighly. The shape of the ROI has no influence using camera technique. We conclude, that camera technique can replace the Oberhausen method with a partially shielded whole body counter.

PhysicsOpticsbusiness.industrylawTime scheduleShielded cableScintillation counterWhole bodybusiness99mTc MAG3Quantitative determinationlaw.inventionGamma camera
researchProduct

Based on Compton Camera

2016

Compton Cameras have been proposed as an alternative to SPECT imaging with Gamma Camera, mainly due to factors such as the electronic collimation, which allows a bigger field of view and provides further information from the acquired events if compared to devices with mechanical collimation. By contrast, this involves a higher amount of data to be processed. In medical devices this leads to waiting times that are generally higher than desirable by the health-care professionals. In this work we have assessed the reconstruction of Compton images by making use of iterative and non-iterative techniques, and also evaluated its performances as a SPECT imaging technique.

Physicsmedicine.diagnostic_testbusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONField of view02 engineering and technologyIterative reconstructionSingle-photon emission computed tomography021001 nanoscience & nanotechnology01 natural scienceslaw.invention010309 opticslawSpect imaging0103 physical sciencesmedicineMedical imagingComputer visionArtificial intelligence0210 nano-technologyElectronic CollimationbusinessImage resolutionGamma camera2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)
researchProduct

Intraoperative Scintigraphy With Portable Gamma Camera for the Localization of Interaortocaval Paraganglioma

2021

A 15-year-old adolescent girl diagnosed of interaortocaval paraganglioma with a positive 123I-MIGB SPECT/CT and 1 unsuccessful prior surgery was operated on with the assistance of a handheld gamma camera. Once the lesion was located and removed, 2 images were taken, one of the surgical field (without 123I-MIGB uptake) and another of the tumor ex vivo (with high 123I-MIGB uptake), confirming that the lesion had been satisfactorily excised. This case highlights the use of a portable gamma camera as a useful tool to locate this rare tumor, with a SPECT/CT positive for 123I-MIGB and a difficult anatomical location suspected.

Prior SurgerySingle Photon Emission Computed Tomography Computed TomographyAdolescentmedicine.diagnostic_testbusiness.industryGeneral MedicineScintigraphymedicine.diseaselaw.inventionParagangliomaLesionRare tumorParagangliomalawmedicineHumansFemaleGamma CamerasRadiology Nuclear Medicine and imagingmedicine.symptomRadionuclide ImagingNuclear medicinebusinessGamma cameraClinical Nuclear Medicine
researchProduct